One: Industry: The controller of the tufting machine handles the way. The problem: When the double-station automatic processing is not in place, the wool is loaded. Analysis and processing: 1: A customer’s terminal is located in Anhui, the problem is that during double-station processing, the burrs are planted before the second station is processed after the first station is processed. 2: Analysis: general There are two possibilities for this situation. One is that the acceleration is not enough, and the other is that the hole pitch is too large (larger than the screw pitch). Before asking the customer, the situation was normal, but this problem kept appearing after changing the fixture. 3: Result: 1: Change the immediate stop to the high stop. 2: Change the skipping distance to a shorter distance, but it must meet the customer's normal hole position processing requirements. Summary: Generally, this kind of situation occurs more frequently at the end customer, which is mainly caused by the end customer changing the fixture without being familiar with the system function and mechanical structure.

Name: p4 four-axis code nail tufting machine S1445

Two: Industry: tufting machine controller processing method:

Problem: the machine cannot be turned on in cold weather After repairing, the number is turned on, but the machine crashes every time when I read the processing file.

Analysis and processing:

1: The company sends an order to the customer to deal with the file-reading crash that the customer responded. 2: Analysis: The crash phenomenon is generally caused by an external signal short circuit, but the customer’s stamping is normal, only when the file is read, and the crash occurs after turning the page, so the problem should be a soft fault. 3: Result: Connect the controller with a computer, check all the processing files, no problems are found. So copy all the customer processing files and create the same number of files on the computer. Then the test machine finds that it is normal, and it can be judged that the problem is still in the processing file. After careful inspection, it is found that there is a product file name that is different from other suffixes, and it is thicker to find that there are spaces. After the modification is correct, everything is normal.

Summary: Sometimes maintenance is also a cautious thing. It requires careful investigation step by step, and finally the problem is slowly found to solve the problem.